Model | A12S 1252 |
---|---|
OUTPUT | |
Rated voltage | 12V |
Rated current | 12.5A |
Rated power | 150W |
Stabilization UWY in depending on changes UWE | ± 1% |
Stabilization UWY in depending on changes IWY | ± 2% |
Tolerance [3] | ± 5% |
Trebles and noises (max.)[2] [2] | 1.5Vp-p |
The time to establish, the time to grow…[4] | 600ms, 20ms / 230Vac under full load |
Sustaining time (type) | 20ms / 230Vac under full load |
Input | |
Voltage range | 180 ÷ 264Vac ; 254 ÷ 372Vdc |
Voltage frequency range | 47 ÷ 63Hz |
Efficiency (type) | 85% |
Current AC (type) | 1.25A / 230Vac |
Security | |
Overload | Scope: 105% ÷ 150% of rated power Type: Alternating on/off output voltage. Automatic return to normal operation after the cause has disappeared. |
Short circuit | Type: Alternating on/off output voltage. Automatic return to normal operation after the causes have disappeared |
Overvoltage | 18 ÷ 20Vdc Type: cut-off of output voltage. Automatic return to normal operation after the cause has disappeared |
Thermal | 140C ± 10oC (detection via IC) Type: Alternating on/off output voltage. Automatic return to normal operation after the cause has disappeared |
Working environment | |
Operating temperature | -10oC ÷ 50oC, |
Work humidity | 20 ÷ 90% relative humidity (non-condensing) |
Storage temperature and humidity | -40oC ÷ 80oC, 10 ÷ 95% relative humidity (non-condensing) |
Safety and electromagnetic compatibility standards [5] | |
Safety standards | Compliance withEN60950-1 |
Insulation strength | WE/WY: 3.0kVAC, WE/GND: 1.5kVAC, WY/GND: 0.5KVA |
Emission standards EMC | Compliance withEN55022 |
Immunity standards EMC | Compliance with EN55024 |
Harmonic current | Compliance with EN61000-3-3; EN61000-3-2 |
Other | |
Dimensions (L x L x W x H) | 214 x 240 x 70 x 54mm |
Weight and packaging | 1.35kg; 16szt. / carton; weight and dimensions of carton: 22.25kg; 49.5 x 33.5 x 14.2cm |
2. Measurements of opacity and noise were made in the 20MHz band using twisted measurement cables and 0.1μF and 47μF capacitors connected in parallel.
3. The tolerance expresses the maximum divergence between the output voltage and the output voltage, taking into account the switching changes, depending on the input voltage changes and the load current changes.
4.The time of setting and rising is measured in the range of 0÷90% of the rated output voltage.
5.In accordance with EN 61204-3, the PSU is a component not intended for installation by the end user. In order to ensure compliance with the compatibility standards, the power supply may
Additional components such as line filter (e.g. 06IB2S) and/or ferrite (e.g. 74271222) must be used on I/O cables. For the final unit containing the power supply, the test should be repeated to verify that the entire system has been met.
- DC power supply
- European input voltage range
- Security: Short circuit / Overload / Overvoltage / Overvoltage / Thermal
- Free-circuit cooling
- Compact size
- Low price