Model A12 6701
Output
Rated voltage 12V
Rated current 6.67A
Output current range 0-6.67A
Rated power 80W
Arteries and noises 1.2Vp-p
Tolerance ±6%
Input
Range Uwe 170 ~ 250 Vac
Frequency range Uwe 47~63 Hz
Efficiency 81%
Input current 0.8A / 230 Vac
Surge current 60A / 230 Vac
Protection
Short circuit Type: cut-off of the output voltage, return to normal operation after the cause of the fault has disappeared
Overload Range: 105 – 140% of the nominal output power Type: alternating start / stop. output voltage. Automatic return to normal operation after the cause has ceased.
Working environment
Working temperature -5oC – +45oC
Ambient humidity 20% – 95% relative humidity (non-condensing)
Storage temperature and humidity -40oC – +45oC, 10% – 95% relative humidity (non-condensing)
Safety and EMC standards
Safety standards EN60950-1
Insulation durability WE/WY: 3kVAC, WE/OBUDOWA:1.5kVac, WY/OBUDOWA: 0.5kVac
Radiated and conducted interference – EMI EN55022
Resistance – EMS EN61000-4-2, -4, -5, -11
Others
Cables Input: 3x 0.75mm2 VDE, Output: 2 x 2 x 0.75mm2 VDE; dł.=300mm
Dimensions (length x length overall x width x height) 240*212*67*51mm
Weight 1.2kg

1. The given parameters (unless otherwise stated) have been measured for the 230VAC input voltage, the rated load current and the ambient temperature of 25 ° C.

2. Tolerance expresses the maximum difference in the output voltage, taking into account changes in switching on, depending on changes in the input voltage and depending on changes in the load current.

3. The power supply unit is a subassembly according to the EN61204 standard intended for installation inside the final product by qualified personnel and can not be used as an independent device. The final effect of electromagnetic compatibility is determined for the final product, then a declaration of conformity is required for the entire installation